Product Type: Luminescence Microplate Reader Model: Feyond-L100
Detection Mode: Glow And Flash Luminescence Supported Microplates: 6- To 384-well Microplates
Wavelength Range: 200–850 Nm Detection Limit: 5 Amol/well Under Optimized Conditions
Linear Dynamic Range: 7 Logs For Flash ATP Assays Standard Filters: 470 Nm And 560 Nm
Highlight

384 Well Luminescence Microplate Reader

,

Luciferase Assays Luminescence Microplate Reader

,

6 Well luminescence plate reader

Product Description

Luminescence Microplate Reader for ATP and Luciferase Assays
Quick Overview

The Feyond-L100 is a compact luminescence microplate reader designed for sensitive glow and flash luminescence assays. It supports 6- to 384-well microplates and uses a low-noise photomultiplier tube to detect weak light signals.

  • Detection mode: Luminescence
  • Supported plates: 6- to 384-well microplates
  • Wavelength range: 200-850 nm
  • Detection limit: 5 amol/well under optimized conditions
  • Standard filters: 470 and 560 nm
  • Main applications: ATP quantification and luciferase reporter assays
Product Description

The Feyond-L100 Luminescence Microplate Reader is developed for laboratories performing sensitive chemiluminescence and bioluminescence assays.

A low-noise PMT detector provides high sensitivity across a wavelength range of 200-850 nm. The system supports both glow and flash measurements, with a linear dynamic range of up to seven logs for flash ATP assays. Its optical design limits well-to-well crosstalk to no more than 0.05%, helping improve data reliability in high-density plates.

The standard 470 and 560 nm filters help reduce background noise during luciferase reporter gene measurements. Other filter wavelengths can be configured according to specific assay requirements.

An optional single or dual automatic injector can dispense reagents directly into 96- or 384-well plates. The injector and detection module work together to capture rapid luminescence signals immediately after reagent addition, making the system suitable for flash-type reactions.

The 10-inch touchscreen and built-in software allow the instrument to operate independently without a computer. Users can create plate layouts, set measurement parameters, analyze data and save assay programs directly on the reader. PC software and FTP data transfer are also supported.

The instrument also provides microplate shaking and temperature-controlled incubation from room temperature plus 4°C to 45°C.

Applications
  • ATP bioluminescence quantification
  • Cell viability and proliferation assays
  • Single-luciferase reporter gene assays
  • Dual-luciferase reporter gene assays
  • Gaussia luciferase assays
  • Chemiluminescence ELISA
  • Reporter gene expression analysis
  • Cytotoxicity studies
  • Enzyme activity measurements
  • Cell-based luminescence assays
  • Glow and flash luminescence detection
  • Molecular biology and pharmaceutical research

The Feyond-L100 is suitable for universities, research institutes, biotechnology companies and pharmaceutical research laboratories. Actual detection performance depends on the reagent system, microplate type, injector settings and assay conditions.

Technical Specifications
Luminescence Detection Parameters
Parameter Specification
Detector PMT
Detection Limit 5 amol/well under optimized conditions
Linear Dynamic Range 7 logs for flash ATP assays
Crosstalk ≤0.05%
Wavelength Range 200-850 nm
Standard Filters 470 nm and 560 nm
Measurement Types Glow and flash luminescence
Basic Parameters
Category Parameter Specification
Plate Support Supported Plates 6- to 384-well microplates
Accessories Injector
Shaking and Incubation Shaking Modes Linear, annular and double annular
Incubation Temperature Room temperature +4°C to 45°C
Temperature Uniformity ±0.5°C at 37°C
Software Software Interface Chinese/English
Screen Size 10-inch
Operation Method Capacitive touchscreen and mouse
Data Capacity 10 GB
PC Compatibility ReaderIt-II PC software
Network Transmission Test reports can be uploaded to a PC server through FTP
Others Instrument Ports 2 × USB Type-A, 1 × USB Type-B, 1 × Ethernet and RS232 injector interface
Power Supply AC 100-240 V, 50/60 Hz
Dimensions (W × D × H) 420 × 487 × 318 mm
Weight 30 kg
Standard Filter Configuration
Filter Wavelength Typical Purpose
LUM-470 470 nm Background reduction for selected luminescence assays
LUM-560 560 nm Background reduction for luciferase-based assays

Product Highlights

Luminescence Microplate Reader for ATP and Luciferase Assays Quick Overview The Feyond-L100 is a compact luminescence microplate reader designed for sensitive glow and flash luminescence assays. It supports 6- to 384-well microplates and uses a low-noise photomultiplier tube to detect weak light ...

Related Products
Quality 0–30000 mg/L Environmental TOC Analyser With High Temperature Catalytic Combustion factory

0–30000 mg/L Environmental TOC Analyser With High Temperature Catalytic Combustion

Environmental TOC Analyzer with High-Temperature Catalytic Combustion RT2201E Environmental TOC Analyzer Designed for Total Organic Carbon (TOC) analysis in environmental and industrial water applications Suitable for wastewater, surface water, groundwater and industrial process water testing High...

Quality Constant Temperature Incubator with 304 Stainless Steel Chamber, Upper Control Panel, 125/210/640/1200 L factory

Constant Temperature Incubator with 304 Stainless Steel Chamber, Upper Control Panel, 125/210/640/1200 L

Product Overview The RHP-9125C and RHP-9210C are electrically heated constant temperature incubators with capacities of 125 L and 210 L. They provide a controlled heated environment for routine laboratory incubation and sample conditioning within the specified temperature range. The upper-mounted ...

Quality Forced Air Constant Temperature Incubator Equipment With 304 Stainless Steel Chamber 45/72L factory

Forced Air Constant Temperature Incubator Equipment With 304 Stainless Steel Chamber 45/72L

Forced Air Constant Temperature Incubator with 304 Stainless Steel Chamber 45/72L Product Overview The Forced Air Constant Temperature Incubator is designed for controlled heating and constant-temperature applications in laboratories. Available in 45 L and 72 L capacities, it features forced air ...

Quality Large Capacity Electric Heating Laboratory Incubator Equipment 125/210L factory

Large Capacity Electric Heating Laboratory Incubator Equipment 125/210L

Large Capacity Electric Heating Laboratory Incubator 125/210L Product Overview The Large Capacity Electric Heating Laboratory Incubator is designed for constant-temperature heating applications in laboratories. Available in 125 L and 210 L capacities, it features a digital temperature controller, ...

Request A Quote

Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.

You can upload up to 5 files and Each file sized 10M max.