| Product Type: | Ducted Laboratory Fume Hood | Available Series: | FMH-DA / FMH-DA(II) |
|---|---|---|---|
| Exhaust Type: | External Ducted Exhaust | Sash Options: | Manual Or Motorized Front Sash |
| Airflow Velocity: | 0.3–0.8 M/s, Adjustable | Control System: | Microprocessor Controller With LCD Display |
| Blower: | Built-in Centrifugal Blower | Work Surface Material: | Chemical-Resistant Phenolic Resin |
| Standard Exhaust Duct: | 10 M PVC Aluminum-Foil Composite Duct | Available External Widths: | 1040 / 1240 / 1540 / 1840 Mm |
| Highlight |
1840mm Laboratory Fume Hood,Ducted Laboratory Fume Hood,Ducted Fume Hood 1040mm |
||
Product Description
The Ducted Laboratory Fume Hood is a negative-pressure ventilation system designed to capture chemical fumes, vapors, aerosols and odors and discharge them through an external exhaust duct. It features adjustable airflow, a built-in centrifugal blower, LCD microprocessor control and a chemical-resistant work surface. Manual and motorized sash options are available.
The Ducted Laboratory Fume Hood draws room air through the front opening and continuously exhausts contaminated air through a connected duct, helping reduce operator and laboratory exposure to airborne chemical contaminants.
Airflow velocity is adjustable from 0.3 to 0.8 m/s. The built-in centrifugal blower provides adjustable-speed extraction, while the bypass grille and sash airfoil help maintain stable airflow as the sash position changes.
The cabinet features an electro-galvanized steel exterior, a compact laminate interior with resistance to weak acids and alkalis, and a chemical-resistant phenolic resin work surface. A liquid collection tank behind the back panel helps collect accidental waste liquid generated during experiments.
The microprocessor controller with LCD display shows the operating status of each function. Additional features include power-failure memory, a UV lamp with timing function, waterproof sockets, a sink, water tap and gas tap.
The FMH-DA series is equipped with a manual sash, while the FMH-DA(II) series has a motorized sash. Available external widths are 1040, 1240, 1540 and 1840 mm.
The fume hood must be connected to a properly designed external exhaust system. The required airflow and exhaust treatment should be determined according to the chemicals used and local laboratory safety requirements.
- Routine chemical preparation and handling
- Acid and alkali experiments within material compatibility limits
- Solvent and reagent operations
- Sample digestion and analytical preparation
- Pharmaceutical and quality-control laboratories
- Educational and research laboratories
- Chemical testing and industrial laboratories
- Procedures that generate fumes, vapors, aerosols or odors
| Specification | 1000 Series | 1200 Series | 1500 Series | 1800 Series |
|---|---|---|---|---|
| Manual Sash Model | FMH-YF1000DA | FMH-YF1200DA | FMH-YF1500DA | FMH-YF1800DA |
| Motorized Sash Model | FMH-YF1000DA(II) | FMH-YF1200DA(II) | FMH-YF1500DA(II) | FMH-YF1800DA(II) |
| External Size (W×D×H)(mm) | 1040×800×2200 | 1240×800×2200 | 1540×800×2200 | 1840×800×2200 |
| Internal Size (W×D×H)(mm) | 820×670×730 | 1020×670×730 | 1320×670×730 | 1620×670×730 |
| Max. Opening | 520mm | 520mm | 520mm | 520mm |
| Work Surface Height | 850mm | 850mm | 850mm | 850mm |
| Display | Microprocessor controller with LCD display | Same | Same | Same |
| Airflow Velocity | 0.3-0.8m/s, speed adjustable | Same | Same | Same |
| Exterior Material | Electro-galvanized steel with powder coating | Same | Same | Same |
| Interior Material | Compact laminate board with good acid and alkali resistance | Same | Same | Same |
| Work Surface | Chemical-resistant phenolic resin | Same | Same | Same |
| Front Window - DA Series | Manual sash | Manual sash | Manual sash | Manual sash |
| Front Window - DA(II) Series | Motorized sash | Motorized sash | Motorized sash | Motorized sash |
| Front Window Material | 5mm toughened glass, height adjustable | Same | Same | Same |
| UV Lamp | 20W×1 | 20W×1 | 30W×1 | 20W×1 |
| UV Lamp Function | With timing function and interlock with front sliding sash; emission wavelength: 253.7nm | Same | Same | Same |
| LED Lamp | 8W×1 | 12W×1 | 16W×1 | 12W×1 |
| Blower | Built-in centrifugal blower, speed adjustable | Same | Same | Same |
| Consumption | 400W | 400W | 500W | 400W |
| Power Supply | AC220V±10%, 50/60Hz; AC110V±10%, 60Hz | Same | Same | Same |
| Illumination | ≥900Lux | ≥900Lux | ≥900Lux | ≥900Lux |
| Sound Emission | ≤68dB(A) | ≤68dB(A) | ≤68dB(A) | ≤68dB(A) |
| Gross Weight (kg) | 286 | 317 | 350 | 400 |
| Shipping Size - Main Body (W×D×H)(mm) | 1190×990×1690 | 1390×990×1690 | 1690×990×1690 | 1990×990×1690 |
| Shipping Size - Base Cabinet (W×D×H)(mm) | 1190×990×900 | 1390×990×900 | 1690×990×900 | 1990×990×900 |
| Shipping Volume (m³) | 3.1 | 3.6 | 4.3 | 5.1 |
Base Cabinet; UV Lamp×1; LED Lamp×1; Waterproof Socket×2; Water Sink; Water Tap; Gas Tap; Gas and Water Remote-Control Valves; 10m PVC Aluminum-Foil Composite Exhaust Duct; Pipe Straps×2
Activated Carbon Filter / HEPA Filter
Socket loading power consumption is not included
Product Highlights
Ducted Laboratory Fume Hood Product Overview The Ducted Laboratory Fume Hood is a negative-pressure ventilation system designed to capture chemical fumes, vapors, aerosols and odors and discharge them through an external exhaust duct. It features adjustable airflow, a built-in centrifugal blower, ...
0–30000 mg/L Environmental TOC Analyser With High Temperature Catalytic Combustion
Environmental TOC Analyzer with High-Temperature Catalytic Combustion RT2201E Environmental TOC Analyzer Designed for Total Organic Carbon (TOC) analysis in environmental and industrial water applications Suitable for wastewater, surface water, groundwater and industrial process water testing High...
Constant Temperature Incubator with 304 Stainless Steel Chamber, Upper Control Panel, 125/210/640/1200 L
Product Overview The RHP-9125C and RHP-9210C are electrically heated constant temperature incubators with capacities of 125 L and 210 L. They provide a controlled heated environment for routine laboratory incubation and sample conditioning within the specified temperature range. The upper-mounted ...
Forced Air Constant Temperature Incubator Equipment With 304 Stainless Steel Chamber 45/72L
Forced Air Constant Temperature Incubator with 304 Stainless Steel Chamber 45/72L Product Overview The Forced Air Constant Temperature Incubator is designed for controlled heating and constant-temperature applications in laboratories. Available in 45 L and 72 L capacities, it features forced air ...
Large Capacity Electric Heating Laboratory Incubator Equipment 125/210L
Large Capacity Electric Heating Laboratory Incubator 125/210L Product Overview The Large Capacity Electric Heating Laboratory Incubator is designed for constant-temperature heating applications in laboratories. Available in 125 L and 210 L capacities, it features a digital temperature controller, ...
Please use our online inquiry contact form below if you have any questions, our team will get back to you as soon as possible.